等離子體診斷用的毫米波準光學系統(tǒng)的設計和測量
DESIGN AND MEASUREMENT OF QUASI-OPTICAL MILLIMETER WAVE SYSTEM FOR PLASMA DIAGNOSTICS
-
摘要: 準光學方法有效地提高了毫米波接收系統(tǒng)在等離子體診斷中的空間分辨率。本文給出了準光學系統(tǒng)的設計公式、設計步驟以及測量的實驗結果。
-
關鍵詞:
- 毫米波; 準光學; 等離子體診斷
Abstract: By means of quasi-optical method, the spatial resolving power of millimeter wave receiving system which is used in plasma diagnostics has been greatly improved. In this paper the formulas and procedures for designing a millimeter wave quasi-optical receiving system are presented and some measured results are given. -
王兆申,科學通報,19(1983), 1166.[2]王兆申,物理學報,32(1983), 1323.[3]C.X. Yu, et al., Plasma Physics and Controlled Fusion, (to be published).[4]Z. S. Wang, et al., Bulletin of the American Physical Society, 28-8(1981), 6022.[5]J. B. Wilgen, et al.,Bulletin of the American Physical Society, 28-8(1983).[6]王兆申,沈?qū)W民,第二屆全國毫米波亞毫米波會議論文集,(1983), 443.[7]H. Kogelnik, T. Li, Proc. IEEE, 10(1966), 1312.[8]I. Ohtera, H. Ujiie, IEEE Trant. on AP, AP-23(1975), 858.[9]S. K. Heald, C. B. Wharton, Plasma Diagnostics with Microwave, New York, 1966, 330.[10]J. C. Mather, IEEE Trans. on AP, AP-29(1981), 967. -
計量
- 文章訪問數(shù): 2125
- HTML全文瀏覽量: 142
- PDF下載量: 684
- 被引次數(shù): 0