靜電離心聚焦系統(tǒng)中相對(duì)論性電子注的理論分析
THEORETICAL ANALYSIS OF THE RELATIVISTIC E-BEAM IN A CENTRIFUGAL ELECTROSTATIC FOCUSING SYSTEM
-
摘要: 本文對(duì)靜電離心聚焦系統(tǒng)中相對(duì)論性電子注與波換能過程進(jìn)行了原理性研究,給出了動(dòng)力學(xué)線性理論分析。對(duì)有關(guān)工程問題進(jìn)行了討論,提出了電子注斜注入的設(shè)想。
-
關(guān)鍵詞:
Abstract: The process of the energy exchange between the E-beam and wave in a cetrifugal electrostatic focusing system is analyzed theoretically in this paper. A kinetic description and discussion related to the project are given. A new method to inject the E-beam obliquely is proposed. -
D. A. Waktis and G. Wade, Proc. IRE, 46(1958), 1700.[2]劉盛綱,物理學(xué)報(bào),15(1959), 575.[3]R. H. Pantell, IRE Trans. on ED, ED-7(1960), 22.[4]R. H. Pantell, ibid., ED-8(1961), 39.[5]I. Alexeff and F. Dyer, Phys. Rev. Lett., 45(1980), 351.[6]I. Alexeff, F. Dyer and W. Nakonieczny, Int. J. IR/MM Waves, 6(1985), 481.[7]Liu Shenggang, 10th Int. Conf. on IR/MM Waves, Dec. 1985.[8]劉盛綱,張世昌,楊中海,陳曉東,歐陽征標(biāo),J. Appl. Phys. 11(1986), 3621.[9]K. R. Chu,成都電訊工程學(xué)院講學(xué)報(bào)告,1981,成都. -